We are co-located in the following Cogent Datacenter
Cogent Data Center
510 Huntmar (Hosting Ctr)
20170 Herndon VA

Interior and exterior security managed 24/7 by permanently assigned staff of Wackenhut guard

Zoned access throughout Data Cente
Biometric hand scanner requires ID card access and hand geometry measurements
Customer IDC access and contacts managed via Siebel
Current government-issued picture ID required
ID badge and biometric hand scan to man trap with badge reader
Second hand scans to gain access to raised floor Biometric scanner captures 3D measurements of hand

Security cameras
Multiple 360 degree cameras with 10x zoom
More than 100 fixed cameras
High speed recorders with DV cassette tapes
Hard drives to eliminate down time for tape swaps and over recording
Minimum 30 day tape storage Generator power * Backup power
Multiple CAT Diesel 20 megawatt generators

Minimum 24 hour fuel storage
Agreements with two major carriers to provide additional diesel fuel
Generators assumes building load within 20 seconds
Generators are tested on weekly basis under load
Tanks are kept at least 80% full at all times

Two utility feeds from independent substations
Diverse paths to the building
Feeds to building are encased in concrete
Fed from two independent substations
Separate transformers fed from both utility sources for redundancy

HVAC chiller systems
Hosting space HVAC system includes (16) AHUs and (16) ACCUs manufactured by Trane
AHUs are DX type and located in the mechanical mezzanine; the ACCUs are located on the roof
There is adequate capacity to withstand a HVAC unit failure or an entire bus failure Cooling is provided by both overhead and under floor air
HVAC systems have wetted media fo r humidification,VFDs for each supply fan, exhaust fans to control building pressure, and economizers to utilize cool outside air
Separate Dectron outside air handling units provide conditioned air for the hosting space
UPS Room cooling is provided by Trane RTUs in a N+1 configuration
Node room cooling is provided by Liebert DX CRAC units in a N+1 configuration

Network facilities - Main Node Room
Multiple fiber providers for diversity - provides diversity and redundancy
Each vendor can deliver additional bandwidth capacity with minimal turn-around time
Can be delivered using existing ‘lit’ fiber
Fiber pathways into the Data Center are truly diverse
Fiber enters building in steel conduit from multiple points in the building


 
 
 
 
 
   
         
Email Marketing
SMS Marketing
Search Engine
Data Entry
Contact Us
Policy
Terms of use
Free Web Hosting
Linux Hosting
Reseller Hosting
Email Hosting
Shared Server
Web Hosting Security
24/7 Monitoring
Data Center Details

Logo Designing, Graphics Designing, Web Site Design, Freelance Website Designing, Website Designing Pakistan, Web Site Design Expert, Web Site Designing, Website Design Expert, Website Designing, Web Design Expert, Web Site Design Pakistan, Website Design Pakistan, Freelance Web Site Design, Freelance Website Designing of Pakistan, web Hosting Pakistan, Web Hosting Karachi, webhosting karachi, webhosting pakistan, linux hosting pakistan, pakistan hosting.